GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
10:40 Feb 7, 2019 |
English to Dutch translations [PRO] Medical - Medical: Instruments / bi-directional steerable guiding sheath | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Barend van Zadelhoff Netherlands Local time: 19:44 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
3 +1 | passageprofiel |
|
passageprofiel Explanation: atrial septal wall, I suppose Het gaat om de dwarsdoorsnede van het instrument bij de passage van het interatriale septum. Je zou dat 'passageprofiel' kunnen noemen. Het boezemtussenschot of interatriale septum (Latijn: septum atriorum) is de wand die de rechter- en linkeratrium van het hart van elkaar scheidt. Een profiel is de contour van de dwarsdoorsnede van een voorwerp. https://nl.wikipedia.org/wiki/Profiel_(object) Profiles: Ultra-low 0.017” tip profile and 0.026” crossing profile‡ Crossing profile is defined as the maximum diameter found between the proximal end of the balloon and the distal tip of the catheter. Definition excerpted from FDA Guidance document titled, Class II Special Controls Guidance Document for Certain Percutaneous Transluminal Coronary Angioplasty (PTCA) Catheters. Emerge 0.026” crossing profile measured on 1.2 x 15 mm (n=5) and 1.5 x 15 mm (n = 5) products. http://www.bostonscientific.com/en-US/products/catheters--ba... The device enables use of a preferred 0.014 to 0.018-inch guide wire to reach and cross the lesion, and a single dual-ended low-profile catheter — one end for delivery and the opposite end for recovery. The preloaded filter/capture wire is ready to flush and deploy with no stylet or introducer. With a 6F guide catheter compatible for all SpideRX filter sizes, the system boasts a 3.2F crossing profile, enabling minimal interaction with the lesion during placement. Multiple filter sizes (3.0, 4.0, 5.0, 6.0, 7.0mm) allow optimal matching of the filter to the vessel size. https://www.dicardiology.com/product/low-crossing-profile-fu... SEAMLESS CROSSING The HeartSpan Fixed Curve Braided Transseptal Sheath is designed to offer seamless dilator to sheath transition for ease of insertion and to reduce trauma when crossing the atrial septum Locking Dilator Sheath and dilator lock to provide a smooth crossing profile during transseptal puncture LOWER CROSSING PROFILE Seamless dilator to sheath transition for smooth advancement across the atrial septum. https://tinyurl.com/y4fuep27 |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.