GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||||
---|---|---|---|---|---|---|
|
17:28 Sep 30, 2012 |
English to German translations [PRO] Tech/Engineering - Chemistry; Chem Sci/Eng / patent application | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: Konrad Schultz Local time: 07:09 | ||||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
3 | amu bin (s.u.) |
| ||
2 | amu Schrittweite |
|
Summary of reference entries provided | |||
---|---|---|---|
Hallo Anja, vielleicht hilft Dir dies weiter: |
| ||
energy bin |
| ||
Erklärung der Massenspektroskopie |
|
Discussion entries: 1 | |
---|---|
amu bin (s.u.) Explanation: "Total Counts (0.07 amu bin)" würde ich wie folgt angeben: "Gesamtimpulse (0,07 amu bin)" Die Masse eines Atoms, Moleküls oder Molekülfragments (Atommasse. Molekülmasse, Formelzeichen m) wird nach dem Internationalen Einheitensysem (SI) in atomaren Masseneinheiten (Formelzeichen u oder amu, englisch:atomic mass unit angegeben. Diese Größe wird auch als 1 Dalton (Formelzeichen D ) bezeichnet. (Aus: Rücker, Neugebauer, Willems, Instrumentelle pharmazeutische Analytik, Wissenschaftl. Verlagsgesellschaft mbH Stuttgart). Die Verwendung von "amu" ist auch in deutschen wissenschaftlichen Papers ziemlich üblich. Die atomare Masseneinheit (Einheitenzeichen: u für unified atomic mass unit, veraltet amu für atomic mass unit) ist eine Maßeinheit der Masse. Sie wird bei der Angabe von Atom- und Molekülmassen verwendet. Ihr Wert ist auf 1/12 der Masse eines Atoms des Kohlenstoff-Isotops 12C festgelegt. https://docs.google.com/viewer?a=v&q=cache:lx6IQDcZzUAJ:www.... Als Masseeinheit werden Dalton (Da) und atomare Masseneinheiten (amu bzw u = atomic mass units), die als 1/12 der Masse des Kohlenstoffisotops 12C festgelegt sind, verwendet. 1 Da = 1 amu = 1,66 x 10-27 kg. https://docs.google.com/viewer?a=v&q=cache:R6uewq98fp0J:www.... "Bin" oder "bin" Üblicherweise wird die PCA-Analyse verwendet, um diese Bestimmung lediglich unter Verwendung der m/z- und der Intensitätsparameter durchzuführen. Somit tragen die Rt-Daten nicht zu der Gesamtanalyse bei. Dieser Kompromiss wird aufgrund der großen Anzahl von Daten in Kauf genommen, die mit ungefähr 5 bis 10 AMU-Punkten pro Ionenpeak von dem Massenspektrometer geliefert werden. Die vorliegende Erfindung beseitigt diesen Nachteil durch die Verwendung von Datenbinning. ... In einer Ausführungsform werden individuelle LC/MS-Chromatogramme in vorbestimmte Fraktionen (oder Bins) getrennt. Diese Bins spiegeln den Rt-Parameter wieder. Die Größe des Bins wird vom Benutzer bestimmt. Beispielsweise kann die Bingröße eine Minute betragen, was Intervallen von einer Minute entlang des Chromatogramms entspricht. Innerhalb jedes Bins werden die Intensitätsinformationen für alle Scans, die während der Binzeit durchgeführt worden sind, für jede Sorte (m/z) summiert, die während des entsprechenden Rt vorhanden ist. http://www.patent-de.com/20051103/DE10392707T5.html counts/bin http://d-nb.info/972176276/34 Gemäß einer Ausführungsform der vorliegenden Erfindung handelt es sich bei dem Detektionschromatogramm um ein einfaches Balkendiagramm (Histogramm). Bei dem Balkendiagramm handelt es sich um eine Reihe von Bins, wobei die Mitte von jedem Bin einer Retentionszeit entspricht und die Breite des Bins einem Retentionszeitintervall entspricht. Das Balkendiagramm wird gebildet, indem für jeden Treffer bzw. Hit der Wert des Bins um 1 erhöht wird, der in das bestimmte Retentionszeitintervall fällt, in dem die Retentionszeit der Masse enthalten ist, die getroffen worden ist bzw. einen Treffer darstellt. http://www.patent-de.com/20070426/DE112005001166T5.html |
| |
Login to enter a peer comment (or grade) |
amu Schrittweite Explanation: alternativ Reference: http://bibliothek.fzk.de/zb/kfk-berichte/KFK2919.pdf |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
9 mins |
Reference: Hallo Anja, vielleicht hilft Dir dies weiter: Reference information: Ich hoffe, Du kannst den Link öffnen, den Text kann ich nämlich nicht hier einfügen: http://books.google.de/books?id=w2KkcfDgzL0C&pg=PT1029&lpg=P... |
| |
Login to enter a peer comment (or grade) |
30 mins |
Reference: energy bin Reference information: energy bin: Monte Carlo simulations of the Galileo energetic particle detector 144.206.159.178/ft/787/72613/1241024.pdf PDF/Adobe Acrobat - Quick View I Jun - 2002 - b Johns Hopkins University Applied Physics Laboratory, Laurel, MD 20723, USA. Received ..... 1MeV ***energy bin***, to the total count rate when the 9:2Rj electron ... PR-08-020 - Jefferson Lab www.jlab.org/exp_prog/proposals/08/PR-08-020.pdf PDF/Adobe Acrobat - Quick View WU Boeglin - o u n ts. Figure 7: Total counts expected per missing ***energy bin***. Included are all the cuts described in this section and overlapping kinematic settings have been ... A Test of Thick-Target Nonuniform Ionization as an ... - Rhessi - Nasa hesperia.gsfc.nasa.gov/.../Spectral%20breaks_nonuniform%20ionizat... PDF/Adobe Acrobat - Quick View Y Su - MD 20771. 2Department of Physics, The Catholic University of America, Washington, DC 20064 ... for establishing the total energy deposited in accelerated electrons, ..... This ensures each ***energy bin*** in our fit range has more than 10 counts. ..... Brown, J. C., Kašparová, J., Massone, A. M., & Piana, M. 2008, A&A, 486, 1023 ... Radiation dose reduction using a CdZnTe-based computed ... www.ncbi.nlm.nih.gov › Journal List › Med Phys HQ Le - 2010 - Department of Radiological Sciences, University of California, Irvine, .... The total count in each ***energy bin*** is obtained by finding the count difference ..... “ Mammographic density and physical assessment of the breast,” AJR, Am. J. Roentgenol. Gahbauer et al., Intensities of Heavy Cosmic-Ray Nuclei iopscience.iop.org/0004-637X/607/1/333/59484.text.html F Gahbauer - 2008 - Currently, measurements of the energy spectra and absolute intensities of these ... extend to a few TeV amu-1 (or total energies around several 1013 eV per nucleus) for the major ... 0.2 TeV amu-1 for some of the secondary nuclei (Binns et al. ..... To derive absolute fluxes from the numbers of events in each ***energy bin*** after ... Image-based spectral distortion correction for photon-counting x-ray ... pdfserv.aip.org/MPHYA6/vol_39/iss_4/1864_1.pdf H Ding - 2012 - Department of Radiological Sciences, University of California, Irvine, ... counts in the five ***energy bins*** with respect to the simulated incident counts from 23.0%, ... VC 2012 Am. Assoc. .... vided into 16 pixels, yielding a total of 64 pixels with each ... The Suprathermal Ion Telescope - Space Physics Research Group ... sprg.ssl.berkeley.edu/impact/SSR/MasonetalSSR.pdf PDF/Adobe Acrobat - Quick View GM Mason - 2008 - In addition to the total fluence (filled blue circles) the figure also shows typical contributions ...... UH (m > 80 amu) counts + background for different ***energy bins*** ... Phys. Rev. Lett. 92 - APS Link Manager - American Physical Society link.aps.org/doi/10.1103/PhysRevLett.92.111301 K Freese - 2004 - 18 Mar 2004 – The total count rate in detectors is not a cosine curve in time and peaks at a different time of year than the standard .... the differential detection rate per unit detector mass ... and is qmax ˆ 2 jvD…t† ÿ vstrj; the maximum nuclear recoil energy ... 6 keVee ***energy bin*** for which DAMA published results. For a 4% ... |
| |
Login to enter a peer comment (or grade) |
2 hrs |
Reference: Erklärung der Massenspektroskopie Reference information: http://www.analytik.ethz.ch/vorlesungen/biopharm/Spektroskop... |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.