GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW) | ||||
---|---|---|---|---|
|
13:52 Sep 9, 2019 |
|
Polish to English translations [PRO] Science - Environment & Ecology | |||||
---|---|---|---|---|---|
|
| ||||
| Selected response from: Agata Liberska United Kingdom Local time: 15:14 | ||||
Grading comment
|
Summary of answers provided | ||||
---|---|---|---|---|
2 +1 | manual gravimetric method |
| ||
3 | manual gravimetric analysis |
| ||
2 | manual (reference/gravimetric) method |
|
manual gravimetric method Explanation: Nie jestem pewna, ale taki termin występuje przy pomiarach jakości powietrza. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4587562/ |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
manual gravimetric analysis Explanation: https://en.wikipedia.org/wiki/Gravimetric_analysis Detailed information on the determination of the LOD and LOQ for gravimetric analysis of airborne dust samples can be found in ISO 15767.9. In practice, it is convenient for the LOD of the gravimetric analysis to be determined as three times the standard deviation of the weight changes of the blank samples. http://www.hse.gov.uk/pubns/mdhs/pdfs/mdhs14-4.pdf |
| |
Login to enter a peer comment (or grade) |
manual (reference/gravimetric) method Explanation: Procesy formowania pyłu PM10. Zgodnie z Rozporządzeniem2 jako metodę referencyjną dla pomiaru pyłu PM10 uznaje się metodę manualną wagową - https://isn.page.link/Z366 ------- In spite of the instrumental nature of the sampler, this method is basically a manual procedure, and all designated reference methods for PM10 are therefore defined as manual methods. - https://www3.epa.gov/ttn/amtic/files/ambient/inorganic/mthd-... - page 8 -------- 2.3.2 SAMPLING POINTS Sampling points amount was determined by both methodologies: a) NP EN 13284-1:2009 Stationary source emissions - Determination of low range mass concentration of dust - Part 1: Manual gravimetric method (for TSP and PM10/PM2,5 sampling), and; b) EPA Method 1 Sample and Velocity Traverses for Stationary Sources (for PGC sampling). - https://pdfs.semanticscholar.org/5338/f47d54cae11012592bb911... - page 66 -------- For PM10, the reference is the manual gravimetric method, the equivalent method an automated filter changer. Both are discussed in EN12341. - http://www.euro.who.int/__data/assets/pdf_file/0019/130762/E... - page 16 |
| |
Login to enter a peer comment (or grade) |
Login or register (free and only takes a few minutes) to participate in this question.
You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.