Glossary entry (derived from question below)
English term or phrase:
creeping opens and shorts
French translation:
ouverture et court-circuits à résistance accroissante (incrémentante, augmentante)
Added to glossary by
Johannes Gleim
Mar 20, 2015 08:38
9 yrs ago
English term
creeping opens and shorts
English to French
Tech/Engineering
Electronics / Elect Eng
Article sur les systèmes de sécurité et la norme EN 54-13:
To further increase reliability and availability of the transmission paths in XXX environments, YYY has also developed a family of active end-of-line (EOL) modules. They act as line terminators that continuously test 2- and
4-wire transmission paths for ***creeping opens and shorts*** according to the procedures and criteria of acceptance as laid out in the norm EN 54-13.
To further increase reliability and availability of the transmission paths in XXX environments, YYY has also developed a family of active end-of-line (EOL) modules. They act as line terminators that continuously test 2- and
4-wire transmission paths for ***creeping opens and shorts*** according to the procedures and criteria of acceptance as laid out in the norm EN 54-13.
Proposed translations
(French)
3 -1 | ouverture et court-circuits à résistance accroissante (incrémentante, augmentante) | Johannes Gleim |
Change log
Mar 20, 2015 14:20: Yana Dovgopol changed "Visibility" from "Visible" to "Squashed"
Mar 25, 2015 17:53: Maria Kopnitsky changed "Visibility" from "Squashed" to "Visible"
Mar 27, 2015 10:24: Johannes Gleim Created KOG entry
Proposed translations
-1
3 hrs
Selected
ouverture et court-circuits à résistance accroissante (incrémentante, augmentante)
NF EN 54-13 Août 2005
Systèmes de détection et d'alarme incendie - Partie 13 : évaluation de la compatibilité des composants d'un système -
http://www.boutique.afnor.org/norme/nf-en-54-13/systemes-de-...
Area Rotating machinery / Operation
IEV ref 411-52-44
en
creeping (of a d.c. motor)
the undesired running at slow speed of a d.c. motor due to residual magnetism
fr
rampage (d'un moteur à courant continu)
fonctionnement indésirable à faible vitesse d'un moteur à courant continu dû au magnétisme rémanent
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
http://iate.europa.eu/SearchByQuery.do?method=searchDetail&l...
Do not mismatch « creeping by « creepage ».
Area Electrical and magnetic devices / Behaviour and use
IEV ref 151-15-50
en
creepage distance
shortest distance along the surface of a solid insulating material between two conductive parts
fr
ligne de fuite, f
distance la plus courte, le long de la surface d'un isolant solide, entre deux parties conductrices
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
Test Resistance
Aiming to increase reliability through early detection of creeping shorts and opens, EN 54-13 introduced defined procedures and criteria of acceptance for the functional tests of fault warning conditions in transmission paths. The test for a creeping open requires the introduction of serial resistance into the transmission path. Starting with the quiescent condition, the resistance must be increased until a fault warning condition is reached and a fault is signaled to the fire panel. Decreasing the resistance by 10% must then make the entire transmission path fully operational again.
This means that all elements that are connected to the tranmission paths remain fully functional, even if elements require higher current values in alarm state compared to the normal state. By the EOL modules it is assured that the line resistances on the tranmission paths are within the limits that are required for flawless functionality. The creeping short test is very similar, requiring parallel resistances. Here, the resistance needs to be reduced until a fault is signaled, and a subsequent increase of the resistance by 10% must bring the transmission path back to normal.
End of The Line
In order to comply with the requirements of EN 54-13, and thus be able to connect detector lines to the fire alarm system in a way that conforms to this standard, XXX has developed a family of active end-of-line (EOL) modules. They act as line terminators that continuously test 2 and 4-wire transmission paths for creeping opens and shorts according to the procedures and criteria of acceptance as laid out in the norm.
http://www.git-security.com/topstories/fire-protection/makin...
Tyco Fire & Integrated Solutions SA / ADT est l‘un des premiers fabricants à obtenir la reconnaissance des systèmes selon EN 54-13 (évaluation de la compatibilité des composants du système) pour les systèmes d‘alarme incendie de la série MZX.
http://www.fr.tyco.ch/document-downloads/Prospekte/Detector/...
-Simple défaut
Simple défaut sur un circuit ouvert ou un circuit fermé (bouclé) d’entrées/sorties (détecteurs, boutons, sirènes, modules de commande, ...) Le système doit être conçu de telle manière qu’un simple défaut à l’endroit le plus défavorable dans un circuit ne puisse pas empêcher le bon fonctionnement de plus d’une des fonctions suivantes:
o la détection incendie automatique;
o le fonctionnement des déclencheurs manuels;
o la diffusion sonore d’une alarme incendie;
o la transmission ou la réception de signaux de et vers les dispositifs d’entrée et de sortie;
o l’activation d'équipements auxiliaires
:
o la simulation des différents défauts possibles (détecteurs retirés de leur socle, réseau ouvert, réseau en court-circuit, ouverture de lignes de sirènes, coupure des sources d'alimentation, coupure du rayon de détection d'un beam, fonctionnement du mode dégradé, encrassement d'un détecteur...) et vérification de la signalisation adéquate des défauts
http://www.cifful.ulg.ac.be/images/stories/Guides_secu_incen...
RÈGLES TECHNIQUES T7
SYSTÈMES DE DÉTECTION AUTOMATIQUE D’INCENDIE
SPÉCIFICATIONS ET MÉTHODES D’ESSAIS
:
7.4.1 Programme d’essais
Les essais sont réalisé selon le § 5.3 de la EN 54-13. Cependant les essais réalisés en laboratoire de coupure de de court-circuit impédant ne s’applique qu’aux circuits de détection aux sens de la norme EN 54-2.
http://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd=...
Explication de mot « impédant » :
Area Earthing and protection against electric shock / Operation
IEV ref 195-04-08
en
impedance earthed neutral system
impedance grounded neutral system (US)
system in which at least one neutral point is earthed through a device having an impedance designed to limit the line-to-earth short-circuit current
fr
réseau à neutre impédant
réseau dont au moins un point neutre est mis à la terre par l’intermédiaire d’un dispositif présentant une impédance conçue pour limiter le courant de court-circuit phase-terre
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
• Afin d'utiliser le système de détection d'incendie conformément à la norme EN 54-13, il est nécessaire
d'interrompre la connexion entre chaque zone conventionnelle et les modules EOL.
• Il convient de respecter la résistance de ligne maximale de 25 Ω pour les lignes conventionnelles avec déclencheurs manuels d'alarme incendie ou détecteurs d'incendie automatiques
http://resource.boschsecurity.com/documents/FLM_420_4_CON_Da...
Remarque!
Notez que la résistance de ligne pour les sorties de relais est limitée à 22,5 ohms
http://resource.boschsecurity.com/documents/Panel_Installati...
Malheureusement, pas de description d'essais détaillée trouvé.
Systèmes de détection et d'alarme incendie - Partie 13 : évaluation de la compatibilité des composants d'un système -
http://www.boutique.afnor.org/norme/nf-en-54-13/systemes-de-...
Area Rotating machinery / Operation
IEV ref 411-52-44
en
creeping (of a d.c. motor)
the undesired running at slow speed of a d.c. motor due to residual magnetism
fr
rampage (d'un moteur à courant continu)
fonctionnement indésirable à faible vitesse d'un moteur à courant continu dû au magnétisme rémanent
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
http://iate.europa.eu/SearchByQuery.do?method=searchDetail&l...
Do not mismatch « creeping by « creepage ».
Area Electrical and magnetic devices / Behaviour and use
IEV ref 151-15-50
en
creepage distance
shortest distance along the surface of a solid insulating material between two conductive parts
fr
ligne de fuite, f
distance la plus courte, le long de la surface d'un isolant solide, entre deux parties conductrices
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
Test Resistance
Aiming to increase reliability through early detection of creeping shorts and opens, EN 54-13 introduced defined procedures and criteria of acceptance for the functional tests of fault warning conditions in transmission paths. The test for a creeping open requires the introduction of serial resistance into the transmission path. Starting with the quiescent condition, the resistance must be increased until a fault warning condition is reached and a fault is signaled to the fire panel. Decreasing the resistance by 10% must then make the entire transmission path fully operational again.
This means that all elements that are connected to the tranmission paths remain fully functional, even if elements require higher current values in alarm state compared to the normal state. By the EOL modules it is assured that the line resistances on the tranmission paths are within the limits that are required for flawless functionality. The creeping short test is very similar, requiring parallel resistances. Here, the resistance needs to be reduced until a fault is signaled, and a subsequent increase of the resistance by 10% must bring the transmission path back to normal.
End of The Line
In order to comply with the requirements of EN 54-13, and thus be able to connect detector lines to the fire alarm system in a way that conforms to this standard, XXX has developed a family of active end-of-line (EOL) modules. They act as line terminators that continuously test 2 and 4-wire transmission paths for creeping opens and shorts according to the procedures and criteria of acceptance as laid out in the norm.
http://www.git-security.com/topstories/fire-protection/makin...
Tyco Fire & Integrated Solutions SA / ADT est l‘un des premiers fabricants à obtenir la reconnaissance des systèmes selon EN 54-13 (évaluation de la compatibilité des composants du système) pour les systèmes d‘alarme incendie de la série MZX.
http://www.fr.tyco.ch/document-downloads/Prospekte/Detector/...
-Simple défaut
Simple défaut sur un circuit ouvert ou un circuit fermé (bouclé) d’entrées/sorties (détecteurs, boutons, sirènes, modules de commande, ...) Le système doit être conçu de telle manière qu’un simple défaut à l’endroit le plus défavorable dans un circuit ne puisse pas empêcher le bon fonctionnement de plus d’une des fonctions suivantes:
o la détection incendie automatique;
o le fonctionnement des déclencheurs manuels;
o la diffusion sonore d’une alarme incendie;
o la transmission ou la réception de signaux de et vers les dispositifs d’entrée et de sortie;
o l’activation d'équipements auxiliaires
:
o la simulation des différents défauts possibles (détecteurs retirés de leur socle, réseau ouvert, réseau en court-circuit, ouverture de lignes de sirènes, coupure des sources d'alimentation, coupure du rayon de détection d'un beam, fonctionnement du mode dégradé, encrassement d'un détecteur...) et vérification de la signalisation adéquate des défauts
http://www.cifful.ulg.ac.be/images/stories/Guides_secu_incen...
RÈGLES TECHNIQUES T7
SYSTÈMES DE DÉTECTION AUTOMATIQUE D’INCENDIE
SPÉCIFICATIONS ET MÉTHODES D’ESSAIS
:
7.4.1 Programme d’essais
Les essais sont réalisé selon le § 5.3 de la EN 54-13. Cependant les essais réalisés en laboratoire de coupure de de court-circuit impédant ne s’applique qu’aux circuits de détection aux sens de la norme EN 54-2.
http://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd=...
Explication de mot « impédant » :
Area Earthing and protection against electric shock / Operation
IEV ref 195-04-08
en
impedance earthed neutral system
impedance grounded neutral system (US)
system in which at least one neutral point is earthed through a device having an impedance designed to limit the line-to-earth short-circuit current
fr
réseau à neutre impédant
réseau dont au moins un point neutre est mis à la terre par l’intermédiaire d’un dispositif présentant une impédance conçue pour limiter le courant de court-circuit phase-terre
http://www.electropedia.org/iev/iev.nsf/display?openform&iev...
• Afin d'utiliser le système de détection d'incendie conformément à la norme EN 54-13, il est nécessaire
d'interrompre la connexion entre chaque zone conventionnelle et les modules EOL.
• Il convient de respecter la résistance de ligne maximale de 25 Ω pour les lignes conventionnelles avec déclencheurs manuels d'alarme incendie ou détecteurs d'incendie automatiques
http://resource.boschsecurity.com/documents/FLM_420_4_CON_Da...
Remarque!
Notez que la résistance de ligne pour les sorties de relais est limitée à 22,5 ohms
http://resource.boschsecurity.com/documents/Panel_Installati...
Malheureusement, pas de description d'essais détaillée trouvé.
Peer comment(s):
agree |
Tony M
: Apologies, you are right and I was wrong; inadequate original context to work from! Presumably, though, the 'augmentant' only applies to the open; I imagine the short is in fact a reducing resistance?
26 mins
|
Thank you! The only question is, how to translate "creeping". I hesitated to apply "rampant lentement" or other circumscriptions.
|
|
disagree |
Herbie
: "ouverture accroissante"?- Does this term exist at all? At least not in electrical engineering.
1 hr
|
This is not the question. It describes the process of deterioration of creepages. The asker is free to rephrase my idea (accroissante, incrémentante, augmentante)
|
|
disagree |
GILLES MEUNIER
: accroissante, ce n'est pas du français
8 days
|
379.000 Ghits. Voir la discussion. Par ailleurs, « accroissante (incrémentante, augmentante » sont des suggestions seulement, illustrant le type de détérioration.
|
4 KudoZ points awarded for this answer.
Comment: "Merci"
Discussion
accroissante f
1. feminine form of accroissant
http://en.wiktionary.org/wiki/accroissante
accroître
participe présent
• accroissant
http://www.larousse.fr/conjugaison/francais/accroître/110
e ) La respiration accroissante remédie à la maigreur
https://books.google.de/books?id=VYi5eRayVtYC&pg=PT53&lpg=PT...
Les socialistes démocratiques, craignant la popularité accroissante du Parti Communiste du Canada, ont décidé qu’il fallait organiser un parti national.
http://scaa.usask.ca/gallery/election/fr/regina.htm
"De la croissance à l’accroissante"
Jeudi 21 Février 2013
http://www.inforeunion.net/De-la-croissance-a-l-accroissante...
Ungefähr 379.000 Ergebnisse (0,62 Sekunden)
https://www.google.de/?gws_rd=ssl#q="accroissant"
I think 'rampant' is an original translation error — remember, it really translates 'crawling', and I think it is inappropriate for a technical translation of 'creeping' (which emphasizes 'moving slowly' rather than 'low to the ground')
If we assume that 'creeping' has the sense of 'getting steadily worse', then how about something like 'progressif'?
We are discussing simulated line failures (interruptions and short-circuiting). Please read the English test description thoroughly (It also contains the context from the question).
http://www.git-security.com/topstories/fire-protection/makin...
The only problem is that 'creeping' in a technical sense does NOT mean 'fugitif'!