Glossary entry (derived from question below)
English term or phrase:
gas load factor/ nozzle momentum criteria
Russian translation:
критерии скорости Саудерса-Брауна / динамического давления в патрубке
Added to glossary by
Enote
Oct 28, 2020 07:32
3 yrs ago
16 viewers *
English term
gas load factor/ nozzle momentum criteria
English to Russian
Tech/Engineering
Mechanics / Mech Engineering
well test separator
System offered shall be capable to operate in wet gas mode and shall be capable of seamless transition between multiphase and wet gas mode.
Bidder shall provide design and preliminary pressure drop calculations for skid and assumptions if any
Also mention gas load factor/ nozzle momentum criteria considered for same.
Bidder shall provide design and preliminary pressure drop calculations for skid and assumptions if any
Also mention gas load factor/ nozzle momentum criteria considered for same.
Proposed translations
(Russian)
3 | критерии скорости Саудерса-Брауна / динамического давления в патрубке | Enote |
4 | расчетные коэфф. нагрузки газа / кинетическая энергия | Pavel Altukhov |
Change log
Nov 2, 2020 19:45: Enote Created KOG entry
Proposed translations
4 hrs
Selected
критерии скорости Саудерса-Брауна / динамического давления в патрубке
Цитата из руководства Shell DEP 31.22.05.11 Gas/liquid separators - type selection and design rules:
The gas load factor, also referred to as k-factor or Souders-Brown velocity, is defined as (формула с размерностью скорости)
This is a superficial gas velocity modified with a gas density scaling factor which accounts to a large extent for the effect of operating pressure.
momentum criteria используется для расчета размера патрубка.
Согласно ему динамическое давление флюида в патрубке должно быть меньше некоторого значения, зависящего от типа входного устройства сепаратора, от 1400 до 8000 Па
The gas load factor, also referred to as k-factor or Souders-Brown velocity, is defined as (формула с размерностью скорости)
This is a superficial gas velocity modified with a gas density scaling factor which accounts to a large extent for the effect of operating pressure.
momentum criteria используется для расчета размера патрубка.
Согласно ему динамическое давление флюида в патрубке должно быть меньше некоторого значения, зависящего от типа входного устройства сепаратора, от 1400 до 8000 Па
4 KudoZ points awarded for this answer.
2 hrs
расчетные коэфф. нагрузки газа / кинетическая энергия
нагрузка на конструкцию со стороны газа и кинет. энергия выходящего потока газа
Something went wrong...