Jul 31, 2015 12:05
8 yrs ago
1 viewer *
English term

Wye-Delta Open Transition

English to Romanian Tech/Engineering Mechanics / Mech Engineering
este vorba despre manualul unui
CONTROLER PENTRU POMPĂ STINGERE INCENDII
ACȚIONATĂ DE MOTOR ELECTRIC


"Series MP300 Across the line Start:
...
Series MP400 Primary Resistance Start:
...
Series MP420 Part-Winding Start:
....
Series MP430 Wye-Delta Open Transition:
There are three contactors for wye-delta starting.
The start contactor and the shorting contactor will close immediately on demand."



Multumesc!!!

Discussion

AndreeaCiorba (asker) Jul 31, 2015:
mai mult context: "This connects the motor leads in the wye configuration.
After the transition time delay the shorting contactor opens and the run contactor closes, thus connecting the motor windings in the delta configuration.
The motor will now run at full speed and deliver rated horsepower to the load."

Proposed translations

3 days 8 hrs
Selected

tranzitie de la conexiune in stea la conexiune in triunghi

.
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Multumesc!"